• Mixed Metal Oxide (MMO) Coated Titanium Wire Anode
  • Mixed Metal Oxide (MMO) Coated Titanium Wire Anode
  • Mixed Metal Oxide (MMO) Coated Titanium Wire Anode
  • Mixed Metal Oxide (MMO) Coated Titanium Wire Anode

Mixed Metal Oxide (MMO) Coated Titanium Wire Anode

Our MMO wire anodes are designed for flexible installation, suitable for direct burial in fine sand or carbonaceous backfill, as well as long-term immersion in freshwater or saline water. Their versatile application scenarios include:
1. Wrapping around pipelines to deliver continuous and close-proximity cathodic protection.
2. Prepacked with coke breeze in canisters for deep well anode installation.
3. Connected to a feed cable at one end or assembled in a piggyback configuration to form a continuous anode system, ideal for under-tank protection.
4. Protecting the internal surfaces of water tanks, where their malleable properties ensure uniform current distribution even in areas with significant water level fluctuations.

  • Mixed Metal Oxide (MMO) Coated Titanium Wire Anode
  • Mixed Metal Oxide (MMO) Coated Titanium Wire Anode

Description

Quality Substrate Material
Our MMO wire anodes are fabricated from high-tensile titanium that complies with the commercial standards of ASTM B348 Grade I and Grade II. The elemental composition limits of the two grades are specified in the table below:

Element

Grade I (Max. Content)

Grade II (Max. Content)

Iron (Fe)

0.20%

0.30%

Carbon (C)

0.08%

0.08%

Nitrogen (N)

0.03%

0.03%

Hydrogen (H)

0.015%

0.015%

Oxygen (O)

0.18%

0.25%

Single Impurity (Each)

0.10%

0.10%

Other Impurities (Total)

0.40%

0.40%

Titanium (Ti)

Remainder

Remainder


Long-Lasting Coating System
The mixed metal oxide (MMO) coatings of our anodes exhibit exceptional chemical stability, performing reliably in diverse environments including soil, mud, freshwater, and seawater, even under low pH conditions. The coating formulations can be customized by blending two or more noble metal oxides, such as iridium oxide (IrO₂), tantalum oxide (Ta₂O₅), and ruthenium oxide (RuO₂), based on specific application requirements. Accelerated life tests conducted by an independent laboratory have verified that our MMO coatings outperform comparable products available in the market.
The technical specifications and applicable scenarios of our two mainstream coating catalysts are detailed as follows:

Technical Parameter

Ir–Ta Mixed Metal Oxide Catalyst

Ir–Ru Mixed Metal Oxide Catalyst

Coating Composition

IrO₂, Ta₂O₅

IrO₂, RuO₂

Coating Thickness

0.5~1 μm

0.5~1 μm

Coating Uniformity

Min. 85%

Min. 85%

Recommended Working Environment

Fine sand, coke breeze, freshwater

Mud, concrete, seawater, high-acidity media, chlorine/oxygen-containing environments

Note: We offer tailored anode production services, with adjustable noble metal oxide ratios and coating thickness to meet clients’ specific demands.

Electrochemical Performance
The current output of our MMO wire anodes varies according to the application medium, ranging from soil to seawater. Extending the anode service life can be achieved by either increasing the coating thickness or reducing the operating current density. The following table presents the maximum allowable current density for anodes of different diameters under various service lifetimes and working environments:

Medium

Lifetime

Current Density (mA/m) - Ø1 mm

Current Density (mA/m) - Ø1.5 mm

Current Density (mA/m) - Ø3 mm

Soil

20 yrs.

52 (16 mA/ft.)

79 (24 mA/ft.)

157 (48 mA/ft.)

 

30 yrs.

35 (11 mA/ft.)

53 (16 mA/ft.)

105 (32 mA/ft.)

 

50 yrs.

21 (6 mA/ft.)

32 (10 mA/ft.)

63 (19 mA/ft.)

Coke Breeze

20 yrs.

320 (97 mA/ft.)

480 (146 mA/ft.)

960 (291 mA/ft.)

 

30 yrs.

213 (65 mA/ft.)

320 (97 mA/ft.)

640 (194 mA/ft.)

 

50 yrs.

128 (39 mA/ft.)

192 (58 mA/ft.)

384 (116 mA/ft.)

Fresh Water

20 yrs.

452 (138 mA/ft.)

672 (205 mA/ft.)

1345 (410 mA/ft.)

 

30 yrs.

300 (91 mA/ft.)

445 (136 mA/ft.)

889 (271 mA/ft.)

 

50 yrs.

181 (55 mA/ft.)

265 (81 mA/ft.)

535 (163 mA/ft.)

Seawater

20 yrs.

805 (245 mA/ft.)

1210 (369 mA/ft.)

2350 (716 mA/ft.)

 

30 yrs.

530 (162 mA/ft.)

811 (247 mA/ft.)

1598 (487 mA/ft.)

 

50 yrs.

325 (99 mA/ft.)

475 (145 mA/ft.)

955 (291 mA/ft.)